<?xml version="1.0" encoding="UTF-8"?>
<rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>Lancaster Foundry Supply</title>
	<atom:link href="http://www.lancasterfoundrysupply.com/feed/" rel="self" type="application/rss+xml" />
	<link>http://www.lancasterfoundrysupply.com</link>
	<description>Just another WordPress weblog</description>
	<lastBuildDate>Tue, 11 Jan 2011 23:11:53 +0000</lastBuildDate>
	<language>en</language>
	<sy:updatePeriod>hourly</sy:updatePeriod>
	<sy:updateFrequency>1</sy:updateFrequency>
	<generator>http://wordpress.org/?v=3.0.4</generator>
		<item>
		<title>Add 100,000 square feet to your core room with no capital investment!</title>
		<link>http://www.lancasterfoundrysupply.com/2010/05/02/article1/</link>
		<comments>http://www.lancasterfoundrysupply.com/2010/05/02/article1/#comments</comments>
		<pubDate>Sun, 02 May 2010 14:58:51 +0000</pubDate>
		<dc:creator>admin</dc:creator>
				<category><![CDATA[Uncategorized]]></category>

		<guid isPermaLink="false">http://beta.lancasterfoundrysupply.com/?p=27</guid>
		<description><![CDATA[Lancaster Foundry Supply is privileged to add Shells Inc. to our list of quality manufacturers. We are excited to represent Shells Inc’s capabilities to help improve your casting production through quality cores, cost-effective solutions, value added time savings, and the elimination of core room bottlenecks. Give us an opportunity to deliver quality on-time cores ready [...]]]></description>
			<content:encoded><![CDATA[Lancaster Foundry Supply is privileged to add Shells Inc. to our list of quality manufacturers.  We are excited to represent Shells Inc’s capabilities to help improve your casting production through quality cores, cost-effective solutions, value added time savings, and the elimination of core room bottlenecks.  Give us an opportunity to deliver quality on-time cores ready for your production.  You will only pay for quality cores, and not production core scrap.

<a href="http://www.shellsinc.com" target="_blank">http://www.shellsinc.com</a>
<table class="newstable" border="1" cellspacing="0" cellpadding="0" width="360">
<tbody>
<tr class="title">
<td colspan="3" width="359"><strong>Shell Machines</strong></td>
</tr>
<tr class="headers">
<td width="120"><strong>Description</strong></td>
<td width="87"><strong>Size</strong></td>
<td width="126"><strong>Orientation</strong></td>
</tr>
<tr>
<td width="120">Redford 16</td>
<td width="87">16 x 16</td>
<td width="126">Vertical Split</td>
</tr>
<tr>
<td width="120">Redford 22</td>
<td width="87">22 x 24</td>
<td width="126">Vertical Split</td>
</tr>
<tr>
<td width="120">Redford 42</td>
<td width="87">9 x 12</td>
<td width="126">Vertical Split</td>
</tr>
<tr>
<td width="120">Redford 43</td>
<td width="87">12 x 13</td>
<td width="126">Vertical Split</td>
</tr>
<tr>
<td width="120">Shalco U180</td>
<td width="87">19 x 28</td>
<td width="126">Vertical Split</td>
</tr>
<tr>
<td width="120">Redford 22</td>
<td width="87">22 x 23</td>
<td width="126">Horizontal Split</td>
</tr>
</tbody>
</table>
<table class="newstable" border="1" cellspacing="0" cellpadding="0" width="360">
<tbody>
<tr class="title">
<td colspan="3" width="359"><strong>Cold Box Machines</strong></td>
</tr>
<tr class="headers">
<td width="120"><strong>Description</strong></td>
<td width="87"><strong>Size</strong></td>
<td width="126"><strong>Orientation</strong></td>
</tr>
<tr>
<td width="120">Alpha Set</td>
<td width="87">Any Size</td>
<td width="126">Air-Set</td>
</tr>
<tr>
<td width="120">B&amp;P CB25</td>
<td width="87">40 x 30</td>
<td width="126">Horizontal Split</td>
</tr>
<tr>
<td width="120">B&amp;P CB50</td>
<td width="87">54 x 54</td>
<td width="126">Horizontal Split</td>
</tr>
<tr>
<td width="120">Gaylord S.A.T.B. 30</td>
<td width="87">24 x 24</td>
<td width="126">Horizontal or Vertical</td>
</tr>
<tr>
<td width="120">Gaylord V.S.T.B. 30</td>
<td width="87">30 x 19</td>
<td width="126">Vertical Split</td>
</tr>
<tr>
<td width="120">Redford 22</td>
<td width="87">22 x 31</td>
<td width="126">Vertical Split</td>
</tr>
<tr>
<td width="120">Shalco U180</td>
<td width="87">30 x 21</td>
<td width="126">Vertical Split</td>
</tr>
</tbody>
</table>]]></content:encoded>
			<wfw:commentRss>http://www.lancasterfoundrysupply.com/2010/05/02/article1/feed/</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
		<item>
		<title>Non Reportable Silica, Slag Coagulants</title>
		<link>http://www.lancasterfoundrysupply.com/2010/05/02/article2/</link>
		<comments>http://www.lancasterfoundrysupply.com/2010/05/02/article2/#comments</comments>
		<pubDate>Sun, 02 May 2010 14:56:57 +0000</pubDate>
		<dc:creator>admin</dc:creator>
				<category><![CDATA[Uncategorized]]></category>

		<guid isPermaLink="false">http://beta.lancasterfoundrysupply.com/?p=25</guid>
		<description><![CDATA[Can your facility benefit from a slag coagulant that is NOT marked with a silica warning? Have you ever trialed a fine sieve product with more surface area to collect the unwanted slag from a furnace or ladle? If either situation may benefit your facility, let us know and we can bring in material for [...]]]></description>
			<content:encoded><![CDATA[<p>Can your facility benefit from a slag coagulant that is NOT marked with a silica warning?  Have you ever trialed a fine sieve product with more surface area to collect the unwanted slag from a furnace or ladle?  If either situation may benefit your facility, let us know and we can bring in material for trial.</p>
<h3>Slag Fine Product Analysis (Fine Particle Size)</h3>
<table width="300" border="1" cellpadding="0" cellspacing="0" class="newstable inline">
  <tbody>
    <tr class="title">
      <td colspan="2"><p align="center"><strong>Elemental Analyses: (typical)</strong></p></td>
    </tr>
    <tr>
      <td>Silicon</td>
      <td align="center">33.8</td>
    </tr>
    <tr>
      <td>Aluminum</td>
      <td align="center">7.2</td>
    </tr>
    <tr>
      <td>Potassium</td>
      <td align="center">3.5</td>
    </tr>
    <tr>
      <td>Sodium</td>
      <td align="center">3.4</td>
    </tr>
    <tr>
      <td>Iron</td>
      <td align="center">0.6</td>
    </tr>
    <tr>
      <td>Calcium</td>
      <td align="center">0.6</td>
    </tr>
    <tr>
      <td>Magnesium</td>
      <td align="center">0.2</td>
    </tr>
    <tr>
      <td>Trace Elements</td>
      <td align="center">0.2</td>
    </tr>
  </tbody>
</table>
<table width="300" border="1" cellpadding="0" cellspacing="0" class="newstable inline">
  <tbody>
    <tr class="title">
      <td colspan="2"><p align="center"><strong>Particle Size Distribution: (typical)</strong></p></td>
    </tr>
    <tr>
      <td>Plus 15 screen</td>
      <td align="center">16%</td>
    </tr>
    <tr>
      <td>Plus 20 screen</td>
      <td align="center">29%</td>
    </tr>
    <tr>
      <td>Plus 30 screen</td>
      <td align="center">37%</td>
    </tr>
    <tr>
      <td>Plus 50 screen</td>
      <td align="center">16%</td>
    </tr>
    <tr>
      <td>Beyond Plus 50 screen</td>
      <td align="center">2%</td>
    </tr>
  </tbody>
</table>
<h3 class="clearboth">Slag Gone Analysis (Coarse Particle Size)</h3>
<table width="300" border="1" cellpadding="0" cellspacing="0" class="newstable inline">
  <tbody>
    <tr class="title">
      <td colspan="2"><p align="center"><strong>Elemental Analyses: (typical)</strong></p></td>
    </tr>
    <tr>
      <td>Silicon</td>
      <td align="center">33.8</td>
    </tr>
    <tr>
      <td>Aluminum</td>
      <td align="center">7.2</td>
    </tr>
    <tr>
      <td>Potassium</td>
      <td align="center">3.5</td>
    </tr>
    <tr>
      <td>Sodium</td>
      <td align="center">3.4</td>
    </tr>
    <tr>
      <td>Iron</td>
      <td align="center">0.6</td>
    </tr>
    <tr>
      <td>Calcium</td>
      <td align="center">0.6</td>
    </tr>
    <tr>
      <td>Magnesium</td>
      <td align="center">0.2</td>
    </tr>
    <tr>
      <td>Trace Elements</td>
      <td align="center">0.2</td>
    </tr>
  </tbody>
</table>
<table width="300" border="1" cellpadding="0" cellspacing="0" class="newstable inline">
  <tbody>
    <tr class="title">
      <td colspan="2"><p align="center"><strong>Particle Size Distribution: (typical)</strong></p></td>
    </tr>
    <tr>
      <td>Plus 15 screen</td>
      <td align="center">32%</td>
    </tr>
    <tr>
      <td>Plus 20 screen</td>
      <td align="center">47%</td>
    </tr>
    <tr>
      <td>Plus 30 screen</td>
      <td align="center">15%</td>
    </tr>
    <tr>
      <td>Plus 50 screen</td>
      <td align="center">2%</td>
    </tr>
    <tr>
      <td>Beyond Plus 50 screen</td>
      <td align="center">2%</td>
    </tr>
  </tbody>
</table>
<div class="clearboth"></div>]]></content:encoded>
			<wfw:commentRss>http://www.lancasterfoundrysupply.com/2010/05/02/article2/feed/</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
	</channel>
</rss>

